فیلترها/جستجو در نتایج    

فیلترها

سال

بانک‌ها



گروه تخصصی








متن کامل


نویسندگان: 

Ullah Rabid | Ullah Toheed | Khan Nadeem

اطلاعات دوره: 
  • سال: 

    2023
  • دوره: 

    3
  • شماره: 

    4
  • صفحات: 

    284-293
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    37
  • دانلود: 

    0
چکیده: 

The presence of heavy metals in water makes water unfit for use and causes various hazardous health problems. This research investigates the physical and chemical properties of the collected industrial effluent samples of different industries and the use of burnt potato peels (BPP) as adsorbents to remove heavy metal ions from industrial effluents. Various parameters such as pH, adsorbent volume, and contact time were investigated. The concentration of heavy metal ions was accurately quantified using complexometric titration and atomic absorption spectroscopic analyses. Various heavy metals such as Co+, Mg+, Fe+, Pb+, and Cd+ were found in the samples with varying concentrations. The burnt potato peels showed the maximum adsorption of about 61% at pH 9, 60 min contact time, 0.5 g of burnt potato peels, and 10 mg/L of sample concentration.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 37

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    2006
  • دوره: 

    3
  • شماره: 

    2
  • صفحات: 

    168-172
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    381
  • دانلود: 

    0
چکیده: 

A simple, rapid and selective complexometric method is proposed for the determination of mercury(II). Mercury(II) and other related metal ions are first complexed with an excess of EDTA and the surplus EDTA is back-titrated with a standard lead nitrate solution at pH 5.0-6.0 (hexamine buffer) using xylenol orange as an indicator. A 0.2% solution of 2-thiazolinethiol in acetone is then added to displace EDTA from the Hg(II)-EDTA complex. The released EDTA is titrated with a standard lead nitrate solution as before. Reproducible and accurate results are obtained in the range of 0.8 g l-1-15.8 g l-1 of mercury with a relative error less than ±0.25% and a coefficient of variation (n = 6) not higher than 0.28%. The interference of various ions was studied and the method was employed for the analysis of mercury in its synthetic alloy mixtures and in complexes.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 381

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

اطلاعات دوره: 
  • سال: 

    2022
  • دوره: 

    99
  • شماره: 

    2
  • صفحات: 

    531-537
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    31
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 31

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
نویسنده: 

GHAFURI HOSSEIN | TALEBI MAJID

اطلاعات دوره: 
  • سال: 

    2014
  • دوره: 

    10
تعامل: 
  • بازدید: 

    194
  • دانلود: 

    0
چکیده: 

NOWADAYS FUNCTIONALIZED GRAPHENE BASED SURFACES HAVE POTENTIAL APPLICATIONS IN CATALYST, ENERGY CONVERSION, ENVIRONMENT PROTECTION AND OTHER APPLIED SCIENTIFIC FIELDS. IN THIS PAPER WE HAVE REPORTED A NEW PROTOCOL FOR SYNTHESIS OF PHOSPHORYLATED GRAPHENE OXIDE (PGO) VIA WET CHEMICAL METHODS. AT FIRST STEP GRAPHENE OXIDE (GO) WAS SYNTHESIZED VIA MODIFIED HUMMERS METHOD. AFTERWARDS THE GO WAS FUNCTIONALIZED BY DIFFERENT CHEMICAL PHOSPHORYLATION METHODS. PRODUCTS WERE CHARACTERIZED BY USING FOURIER TRANSFORM INFRARED SPECTROSCOPY (FTIR), RAMAN SPECTROSCOPY; POWDER X-RAY DIFFRACTION (XRD), SCANNING ELECTRON MICROSCOPY (SEM), ENERGY-DISPERSIVE ANALYTICAL X-RAY (EDAX) SPECTROSCOPY, BET METHOD (FOR SURFACE AREA CALCULATION), THERMAL GRAVIMETRIC ANALYSIS (TGA) AND DIFFERENTIAL THERMOGRAVIMETRIC (DTG) ANALYSIS (FOR THERMAL STABILITY MEASUREMENT). THEN BY USING ACCURATE BACK TITRATION METHOD IN PRESENCE OF PH METER CONTROL, PGO SURFACE ACIDITY HAS BEEN MEASURED. CHARACTERIZATION RESULT AND TITRATION PROCEDURE REVEALED THAT; PGO POSES DISTINCT PHYSICAL AND CHEMICAL PROPERTIES; SUCH AS SOLVENT DISPERSITY, ACIDITY BEHAVIOR, ELECTRICAL BEARING, CATION EXCHANGE CAPABILITY, ALTERED MORPHOLOGY AND CRYSTALLINITY, AND ALSO IT POSES BETTER THERMAL STABILITY; IN COMPARISON WITH RARE GO SUBSTRATE.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 194

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0
نویسنده: 

Izadmanesh Yahya | GHASEMI JAHAN B.

اطلاعات دوره: 
  • سال: 

    2015
  • دوره: 

    21
تعامل: 
  • بازدید: 

    155
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

A PH GRADIENT FLOW-INJECTION METHOD [1-3] FOR SIMULTANEOUS DETERMINATION OF NICKEL AND COPPER IN AQUEOUS SOLUTIONS WITH 4- (PYRIDYLE-2-AZO) RESORCINOL (PAR) HAS BEEN DEVELOPED. PH GRADIENT IS CREATED ALONG THE REACTION TUBE BY INJECTING A SMALL AMOUNT OF ACIDIC SOLUTION OF METAL IONS INTO THE FLOW OF BASIC SOLUTION OF LIGAND....

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 155

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0
اطلاعات دوره: 
  • سال: 

    1395
  • دوره: 

    35
  • شماره: 

    1
  • صفحات: 

    53-59
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    2596
  • دانلود: 

    844
چکیده: 

در این پژوهش، ترسیب منیزیم هیدروکسید با خلوص بالا از Tachyhydrite مورد بررسی قرار گرفت. Tachyhydrite ماده معدنی ناپایدار، با فرمول شیمیایی 2MgCl2CaCl212H2O، جزء کمیاب در رسوبات باقی مانده از تبخیر آب دریا و شورآبه ها می باشد که می تواند ماده اولیه مناسبی برای تهیه منیزیم هیدروکسید باشد. دراین پژوهش روشی اتخاذ شد که ازیک سو تولید انبوه فرآورده مقرون به صرفه بوده و از سوی دیگر درصد خلوص آن بیش از 99 درصد بوده و میزان کلسیم موجود در آن زیر حد مجاز باشد. برای این منظور دوغاب کلسیم هیدروکسید به محلولTachyhydrite در آب اضافه شد. به منظور لخته سازی از پلی الکترولیت آنیونی استفاده شد. این بررسی نشان داد که تهیه منیزیم هیدروکسید با خلوص بالای 99 درصد با بهینه سازی شرایط از جمله میزان غلظت منیزیم در محلول، چگونگی افزایش دوغاب در طول زمان واکنش، دمای واکنش و pH محلول، امکان پذیر است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 2596

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 844 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
نویسندگان: 

LIANG Y.

اطلاعات دوره: 
  • سال: 

    2006
  • دوره: 

    3
  • شماره: 

    3
  • صفحات: 

    209-219
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    367
  • دانلود: 

    0
چکیده: 

During the past decade, isothermal titration calorimetry (ITC) has developed from a specialist method to a major, commercially available tool in the arsenal directed at understanding molecular interactions. At present, ITC is used to study all types of binding reactions, including protein-protein, protein-ligand, DNA-drug, DNA-protein, receptor-target, and enzyme kinetics, and it is becoming the method of choice for the determination of the thermodynamic parameters associated with the structure transformation of one molecule or non-covalent interaction of two (or more) molecules. Here, the new applications of ITC in protein folding/unfolding and misfolding, as well as its traditional application in molecular interaction/recognition are reviewed, providing an overview of what can be achieved in these fields using this method and what  developments are likely to occur in the near future.      

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 367

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

SABOURI A.A.

اطلاعات دوره: 
  • سال: 

    2006
  • دوره: 

    3
  • شماره: 

    1
  • صفحات: 

    1-21
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    447
  • دانلود: 

    0
چکیده: 

Thermodynamics of biomacromolecule ligand interaction is very important to understand the structure function relationship in proteins. One of the most powerful techniques useful to obtain additional information about the structure of proteins in biophysical chemistry field is isothermal titration calorimetry (ITC). An ITC experiment is a titration of a biomacromolecule solution by a solution containing a reactant (ligand) at constant temperature to obtain the exchanged heat of the reaction.  The total concentration of ligand is the independent variable under experimental control. There are many reports on data analysis for ITC to find the number of binding sites (g), the equilibrium constant (K), the Gibbs free energy of binding process (DG), the enthalpy of  binding (DH) and the entropy of binding (DS). Moreover, ITC gives information about the type of reaction, electrostatic and hydrophobic interactions, including determination of cooperativity characterization in binding process by calculating the Hill coefficient (n). A double reciprocal plot and a graphical fitting method are two simple methods used in the enzyme inhibition and metal binding to a protein. Determination of a binding isotherm needs more ITC experiments and more complex data analysis. Protein denaturation by ligand includes two processes of binding and denaturation so that ITC data analysis are more complex. However, the enthalpy of denaturation process obtained by ITC help to understand the fine structure of a protein.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 447

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1382
  • دوره: 

    10
  • شماره: 

    3 (مسلسل 29)
  • صفحات: 

    47-52
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1043
  • دانلود: 

    155
چکیده: 

عفونت با ویروس هپاتیت B از مشکلات عمده بهداشتی در جهان است و تنها راه مطمئن برای جلوگیری از ابتلای به این بیماری، واکسیناسیون می باشد. این مطالعه به منظور بررسی سطح ایمنی 5 سال بعد از واکسیناسیون هپاتیت B و در کودکان انجام شده است. تعداد 242 کودک 6 ساله بدو ورود به دبستان که در سال اول تولد واکسینه شده بودند، انتخاب و سطح سرمی آنتی بادی ضد آنتی ژن سطحی ویروس هپاتیت B در آنها بررسی شد. نتایج بدست آمده نشان داد که در 79 نفر (32.6 درصد) بعد از گذشت 6-5 سال سطح آنتی بادی کمتر از حد محافظت کننده علیه بیماری هپاتیت B است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1043

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 155 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 2
اطلاعات دوره: 
  • سال: 

    1398
  • دوره: 

    38
  • شماره: 

    1 (پیاپی 91)
  • صفحات: 

    223-229
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    820
  • دانلود: 

    276
چکیده: 

در این پژوهش، اندازه گیری نیتروژن با سه روش در فرآورده های نفتی و نفت خام خوراک ورودی پالایشگاه اصفهان انجام شد و نتیجه-های به دست آمده با یک دیگر مقایسه شدند. در روش نخست (تیتراسیون pH متری) نیتروژن نمونه ها پس از هضم و تقطیر توسط دستگاه میکروکجلدال، توسط تیتراسیون pH متری اندازه گیری شد. در روش دوم (روش نسلر)، نیتروژن نمونه ها پس از تقطیر میکروکجلدال، با دستگاه اسپکتروفوتومتر و در حضور معرف نسلر اندازه گیری شد و در روش سوم (اندازه گیری توسط تیتراسیون مستقیم) پس از انجام میکروکجلدال، تیتراسیون با سولفوریک اسید در حضور شناساگر متیل سرخ، انجام شد. پیش از اندازه گیری نیتروژن در برش های نفتی سبک، استخراج توسط روش استخراج مایع مایع با سولفوریک اسید غلیظ در یک قیف جدا کننده انجام می گرفتنتیجه آماری جواب های تجزیه های مکّرر با هر سه روش نشان داد که از نظر درستی اندازه گیری، هر سه روش یاد شده دارای درستی یکسانی می باشند و زمان صرف شده برای تجزیه با روش تیتزاسیون مستقیم از همه بیش تر و روش نسلر کوتاه تر است؛ اما پیچیدگی روش نسلر از روش های تیتراسیون بیش تر است. مقدار نیتروژن نفت در خوراک ورودی با توجه به روش نسلر بین 3/1-0/1 گرم بر لیتر بود و این مقدار در فراورده های نفتی بین 0/4300-1/0 میلی گرم بر لیتر در نوسان بود که در بازه ی استاندارد جهانی می باشد. در پایان، نتیجه آماری جواب ها نشان داد که روش اندازه گیری تیتراسیون pH متری روشی مناسب برای چنین اندازه گیری ها است و دارای دقت قابل پذیرشی نیز می باشد. سپس روش رنگ سنجی نسلر جواب قابل پذیرشی برای نمونه های با نیتروژن کم تر دارد ولی دقت روش پایین است و در سرانجام تیتراسیون مستقیم قرار می گیرد که دقّت آن از دو روش دیگر کم تر است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 820

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 276 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button